Removing ITB
-
Open the upper right door of the device.
-
Press the blue lever down on the left side to lower the Secondary Transfer Assembly.
Figure : Lower the Secondary Transfer Assembly
-
Grasp the small handles on the ITB and then pull the ITB out of the product until two large handles expand along the right- and left-side of the ITB.
Figure : Pulling the ITB out of the product
Figure : Expanded handles
-
Grasp the large handles on the ITB and then pull the ITB straight out of the product to remove it.
Figure : Pulling the ITB out of the product
Preparing ITB for Shipment
Spread out a few sheets of paper on a flat surface to collect the small amount of waste toner that may fall from the ITB.
Gently set the ITB vertically on these sheets of paper as shown below (with the handles up). Grasp the ITB by the two blue handles at the top. Lift the ITB and very lightly tap the end opposite the handles (the cleaning section) on the paper about 10 times. This will cause the waste toner to collect around the auger in the cleaning section. This waste toner will be removed when the ITB is reinstalled.
Figure : Set the ITB vertically with the handles up
Reinstalling ITB
-
The ITB is reinstalled in a slight upward angle. Grasp the ITB by the large blue handles and aim it upwards into the slot in the device. An easy way to align it is by touching the end of ITB to the top part of the slot and then push it in, using the top of the slot as the guide.
Figure : Reinstalling ITB