LEDs on Steady
|
Explanation
|
Action
|
Plain+ Load Media+ Error
|
Servo error in the x axis (media axis)
|
Clear media binding
|
Plain+ Error+ Ready
|
RS232 data overflow
|
Check baud rate, parity, cable, Cycle power, resend plot
|
Load Media+ Error+ Film
|
Servo error in the y axis (carriage axis)
|
Cycle power. With power off manually move carriage
|
Plain+ Load Media+Error+film
|
Problems with the free movement
|
With power off manually move of the carriage
|
Plain+ Error+ Film+Normal
|
Electrical error
|
Reseat all cartridges, Clean contacts
|
Plain+ Error+ Normal+ Roll
|
Firmware failure
|
Cycle power, reseat all cartridges, clean contacts
|
Plain+ Error+ Film+Fast+Roll
|
Cartridge alignment firmware error
|
Cycle power, reseat all cartridges
|
Error+ Film
|
DRAM or SIMM DRAM failure. Or One or more of the cartridges is missing, making bad contact, or is the wrong type.
|
Cycle power, service. Insure all cartridges are seated and working properly.
|
Error+ Fast
|
Swath RAM test failure
|
Cycle power, service
|
Error+ Normal
|
Not enough memory to allocate internal data structures
|
Cycle power, service
|
Error + Coated
|
The printer detects that there is a short circuit in one of the addresses that send signals to the cartridges. Or One or more of the cartridges is missing, making bad contact, or is the wrong type.
|
Insure all cartridges are seated and working properly.
|
Error+ Film + Ready
|
Failure of RS232 loopback test.
|
Cycle power, service
|
Error+ Ready+ Roll
|
Special firmware error
|
Cycle power, service
|
Plain+ Error+ Fast
|
Error detected in EEROM
|
Cycle power, service
|
Plain+ Error+ Roll
|
Processor fault
|
Cycle power, service
|
Plain+Load Media+Error+Fast
|
Error in media axis servo feedback loop
|
Cycle power, service
|
Plain+Error+ Film+Fast
|
Not enough memory for the sensor data structure
|
Cycle power, service
|
Plain+ Error+ Film+ Ready
|
Failure of Centronics READ
|
Cycle power, service.
|
Plain+ Error+ Fast+ Roll
|
Communication broken between the 2 processors on the main PCA
|
Cycle power, service
|
Plain+Load Media+Error+Film+Fast
|
Error in bail lift mechanism (It is the carriage that tests to see whether the bail is in the correct position)
|
Cycle power, service
|
Load Media+ Error+ Normal
|
Error in x axis calibration
|
Cycle power, service
|
Load Media+Error+Film+Fast
|
Error in y axis encoder
|
Cycle power, service
|