solution Contentsolution Content

HP LaserJet Pro - Troubleshoot 54.11xx (color density calibration) and 54.14xx (CPR sensor) messages

Troubleshoot 54.11xx (color density calibration) and 54.14xx (CPR sensor) messages

This document provides information about how to resolve common error messages related to color density calibration and the color plane registration sensor. It does not contain all of the possible error codes for HP LaserJet Pro printers.
The following table lists common control panel messages and event codes for HP LaserJet printers. It also lists descriptions of the codes and the actions recommend to resolve the errors.
Control panel message/ Event code
Description
Recommended action
54.1100
Black density out of range
These errors can all occur during the color calibration process.
If print quality is acceptable, continue printing.
If a toner cartridge is in the Very Low state, replace the cartridge, and then calibrate the printer.
If the error persists after replacing the toner cartridge, the sensor might need to be replaced. Contact HP support: www.hp.com/go/support
54.1101
Cyan density out of range
54.1102
Magenta density out of range
54.1103
Yellow density out of range
54.1400
Color plane registration sensor error