HP Z400 Workstation has revolutionary new architecture and
power that will redefine multi-tasking, the HP
Z400 Workstation helps accomplish more
with every minute of time and every dollar of investment.
Feature
|
Description
|
Chipset
|
Intel X58 Express
|
Super I/O Controller
|
SMSC SCH5327, Rev B
|
Processor Socket
|
Single LGA1366
|
Memory Modes
|
Channel Interleaved
|
Memory Speed Supported
|
800 MHz, 1066 MHz and 1333 MHz DDR3
|
Processors
|
|
Memory
|
note:
AMO
note: |
Graphics
|
Professional 2D:
|
Entry 3D:
|
|
Mid-range 3D:
|
|
High End 3D:
|
|
Monitors
|
|
Input Devices
|
|
Power Supply
|
475 W wide-ranging, active Power Factor Correction, 85% Efficient.
|
Source voltage
|
Description
|
+3.3V
|
PCI, PCIe, audio, clocks, chipset, super I/O, BIOS ROM, and onboard logic
|
+5.1V
|
Storage (hard disk drive, optical disk drive, diskette drive), PCI, PCIe, chipset, audio, keyboard/mouse, and USB
|
+12 V-CPU
|
Input to onboard regulator that supplies power to CPU and CPU fan
|
+12 V-B
|
PCI, PCIe, and system fans
|
+12 V-D
|
Storage (hard disk drive, optical disk drive, diskette drive), graphics adapter, and input to onboard regulator that supplies power to memory
|
V12N
|
PCI and serial ports
|
+5 V-SB
|
Sleep circuitry
|
Voltage rail
|
475W maximum continuous current
|
+12 V-CPU
|
17.5A
|
+12 V-B
|
17.5A
|
+12 V-D
|
18.0A
|
V12N
|
0.30A
|
+5 V-SB
|
2.25A
|
3.3V
|
15.0A
|
5.1V
|
21.0A
|
caution:Do not exceed 475 watts of total continuous output power.Maximum combined power on 3.3V and 5.1V is 110W.Maximum combined current on +12V(CPU,B,D) is 38A.
Item
|
Description
|
|
Power supply
|
475W Wide Ranging, Active PFC and 85% efficient
|
|
Operating voltage range
|
90 – 269 VAC
|
|
Rated voltage range
|
100–240 VAC
|
118 VAC
|
Rated line frequency
|
50–60 Hz
|
400 Hz
|
Operating line frequency range
|
47–66 Hz
|
393–407 Hz
|
Rated input current
|
10A @ 100-127 VAC
6A @ 200–240 VAC
|
10A @ 118 VAC
|
Heat dissipation
(Configuration and software dependent)
|
Typical 954 Btu/hr = (240.3 kg-cal/hr)
Maximum 1977 Btu/hr = (498.2 kg-cal/hr)
|
|
Power supply fan
|
One fan, 92mm x 25mm, variable speed
|
|
FEMP Standby Power compliant @115V (<2W in S5 – Power Off)
|
Yes
|
|
EuP Compliant @230V (<1w in S5 – Power Off)
|
Yes
|
|
Built-in Self Test LED
|
Yes
|
|
Surge tolerant full ranging power supply (withstands power surges up to 2000V)
|
Yes
|
|
Power Consumption in sleep mode (as defined by ENERGY STAR) - Suspend to RAM (S3) (Instantly Available PC)
|
<6 watts
|
caution:Using the Energy Save Monitor feature with monitors that are not ENERGY STAR qualified can cause video distortion when an Energy Save timeout occurs.
note:ENERGY STAR is not supported on Linux workstations.If it is necessary to restore the operating system, you must also reset the ENERGY STAR settings (if applicable) after the restore.
note:A preinstalled Windows Vista Business operating system does not contain a Cool Tools icon, shortcut or folder, but several of the tool programs are included, such as Performance Tuning Framework.
note:The ambient upper limit of 35 C is only good up to 1524 M (5000 FT) elevation. There is a 1 C per 304.8 M (1000 FT) derating above 1524 M (5000 FT). So, at 3,048 M (10,000 FT), the upper ambient air temperature limit is 30 C.
Weight (Typical configuration)
|
13.5-19.6 kg (29.8-43.2 lb.)
|
Chassis Dimensions
|
Height: 45.0 cm (17.7 in.)
Width: 17.0 cm (6.7 in.)
Depth: 44.5 cm (17.5 in.)
|
Feature
|
Description
|
Operating System
|
|
Temperature
|
Operating: 5 to 35°C (40 to 95°F)
Non-operating: -40 to 60°C (-40 to 140°F)
note: |
Humidity
|
Operating: 8 to 85% Relative Humidity (RH), non-condensing
Non-operating: 8 to 90% Relative Humidity, non-condensing
|
Altitude
|
Operating: 0 to 3,048m (10,000 ft.)
Non-operating: 0 to 9,144m (30,000 ft.)
|
Shock
|
Operating: ½-sine: 40g, 2-3ms
Non-operating:
note: |
Vibration
|
Operating Random: 0.5g (rms), 5-300 Hz
Non-Operating: random: 2.0g (rms), 10-500 Hz
note: |