Maintenance & Service Guide: HP Pro 3120 MT, HP Pro 3125 MT, HP Pro 3130 MT

Microtower models

Desktop Dimensions
Height
Width
Depth
15.10 in
7.27 in
16.16 in
38.35 cm
18.46 cm
41.05 cm
Approximate Weight
HP Pro 3120
HP Pro 3125
HP Pro 3130
17.5 lb
17.7 lb
18.4 lb
7.94 kg
8.03 kg
8.35 kg
Temperature Range
Operating
Nonoperating
50° to 95°F
-22° to 140°F
10° to 35°C
-30° to 60°C
Relative Humidity (noncondensing)
Operating
Nonoperating (38.7°C max wet bulb)
10-90%
5-95%
10-90%
5-95%
Maximum Altitude (unpressurized)
Operating
Nonoperating
10,000 ft
30,000 ft
3048 m
9144 m
note:
Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no direct sustained sunlight. Maximum rate of change is 10° C/Hr. The upper limit may be limited by the type and number of options installed.
Power Supply
Operating Voltage Range
Rated Voltage Range
Rated Line Frequency
115V
90-132 VAC
100-127 VAC
50-60 Hz
230V
180-264 VAC
200-240 VAC
50-60 Hz
Power Output
300 W
300 W
Rated Input Current (maximum)1
6A @ 100 VAC
3A @ 200 VAC
1This system utilizes a passive power factor corrected power supply. The power factor correction is present in the 230V operating mode only. This allows the system to pass the CE mark requirements for use in the countries of the European Union. This supply requires the use of an input voltage range select switch.