HP Z800 Workstation - Power Supply Specifications

Power supply specifications

Power supply specifications
Item
Description
Power supply
850W Wide Ranging, Active PFC
1110W Wide Ranging, Active PFC*
Operating voltage range
90-269 V ac
90-269 V ac
Rated voltage range
100-240 V ac
118 V ac
100-240 V ac
118 V ac
Rated line frequency
50-60 Hz
400 Hz
50-60 Hz
400 Hz
Operating line frequency range
47-66 Hz
393-407 Hz
47-66 Hz
393-407 Hz
Rated input current
11A@100-127 V ac
5.5A@200-240 V ac
11.0A@118 V ac
12.0A@100 V ac, 1110 W
12.0A@115 V ac, 1250 W
10.0A@200-240V ac, 1250 W
12.0A@118 V ac, 1250 W
Heat dissipation
(Configuration and software dependent)
Typical: 1707 Btu/hr = (430 kg-cal/hr)
Max: 3538 Btu/hr = (892 kg-cal/hr)
Typical: 2128 Btu/hr = (536 kg-cal/hr)
Max: 4457 Btu/hr = (1123 kg-cal/hr)
Max2: 5019 Btu/hr = (1265 kg-cal/hr)
Power supply fan
2x80x25 mm variable speed
2x80x25 mm variable speed
ENERGY STAR Qualified (config dependent)
Yes
Yes
80 PLUS compliant
80 PLUS BRONZE compliant
80 PLUS SILVER compliant
FEMP Standby Power compliant @115V (<2 W in S5 – Power Off)
Yes
Yes
EuP compliant @ 230V (<1 W in S5 -- Power Off)
Yes
Yes
Power Consumption in sleep mode (as defined by ENERGY STAR) - Suspend to RAM (S3) (Instantly Available PC) measured at 115V.
<20 W
<20 W
Built-in Self Test LED
Yes
Yes
Surge Tolerant Full Ranging Power Supply (withstands power surges up to 2000V)
Yes
Yes
*See the Site Prep Guide for additional information on input voltage restrictions and how to obtain 1250 W output.