SUPPORT COMMUNICATION- CUSTOMER ADVISORY

Document ID: c05866127

版本: 1

諮詢: HP Z4 G4 工作站 - AC 電源中斷後,I210 LAN 控制器不會回應網路喚醒封包

Notice:: The information in this document, including products and software versions, is current as of the release date.The document is subject to change without notice.

Release date : 26-Dec-2017

Last updated : 03-Jan-2018

DESCRIPTION
若 HP Z4 G4 遇到 AC 電源中斷,系統主機板整合式 NIC(LOM 連接埠)I210 將無法使用網路喚醒功能以遠端開機。

SCOPE
此行為只適用於搭載 Intel I210 LOM 的 HP Z4 Gen4 平台。 目前無變更硬體設計以改變此行為的計畫。
系統:
  • HP Z4 G4 工作站
作業系統:
  • 無特定作業系統
RESOLUTION
若客戶需要系統能在 AC 電源中斷後進行網路喚醒,建議採取以下方法:
-使用 Intel I219 LOM。
-或者,有一項用於「AC 電源中斷後」的 BIOS 設定,可變更為「開機至 S0」,這會讓 BIOS 偵測到 AC 電源中斷後嘗試開機至 S0。 這樣系統會開機,並讓 I210 能從睡眠、休眠或關機狀態進行網路喚醒。

Hardware platforms affected : HP Z4 G4 Workstation

Operating systems affected : Not applicable

Software affected : Not applicable

Support Communication Cross Reference ID : IA05864376

HP Inc. shall not be liable for technical or editorial errors or omissions contained herein.The information provided is provided "as is" without warranty of any kind.To the extent permitted by law, neither HP or its affiliates, subcontractors or suppliers will be liable for incidental, special or consequential damages including downtime cost; lost profits; damages relating to the procurement of substitute products or services; or damages for loss of data, or software restorationThe information in this document is subject to change without notice.HP Inc. and the names of HP products referenced herein are trademarks of HP Inc. in the United States and other countries.Other product and company names mentioned herein may be trademarks of their respective owners.