solution Contentsolution Content

HP Designjet 700 Series Printers - How to Configure the Interface for Serial

Configuring the Interface for Serial

The following table shows the settings available for the printer's serial interface parameters, the factory defaults, and the most likely requirements for different computers.
Serial (RS-232-C) Settings
Likely requirement for ...
Parameter
Available settings
PC
UNIX (R)
Baud rate
1200
2400
4800
9600*
19200
38400
9600*
9600*
Parity (1)
None (0)*
Even
Odd
None*
None*
* = factory default
note:
Parity of None = 8 data bits, 1 stop bit
Parity of Even or Odd = 7 data bits, 1 stop bit
The settings on the printer must match those of the computer and software sending the data. Use their documentation to find the requirements. If in doubt, try with the above suggestions. If the printer's defaults already match the requirements, then you can skip the rest of this task.

To Change the Printer’s Serial Interface Settings

Through the front-panel display, you can create and save two sets of configurations for the serial interface, called Configurations A and B. By default, they are set to the factory defaults shown in the table above. The factory default configuration is always available as well, giving you up to three stored configurations to choose from.
The instructions that follow explain how to specify and apply Configuration A.
  1. On the front-panel display, change the Menu mode from Short to Full.
    1. Press ENTER.
    2. Press the DOWN ARROW key twice to the Utilities menu. Press ENTER.
      Menu Mode = Full
      Press ENTER.
      Press the DOWN ARROW key to the Short menu mode. Press ENTER to save settings.
      In Short Menus
    3. Choose Queuing and Nesting and press the Down Arrow key
    4. Choose Demos and press the Down Arrow key
    5. Choose Utilities and press the Down Arrow key
      In the Utilities menu
      Short
      Press ENTER
    6. In the Menu mode
      Short *
      Press the Down Arrow key then press ENTER.
    7. In the Utilities menu
      Full
      Press the Previous button
    8. In the Full Menus mode
      Utilities
      Press the Down Arrow key
  2. Go to the routine for defining a new serial configuration.
    1. In the Full Menus mode
      I/O setup
      Press the Down Arrow key
      Press ENTER
    2. In the I/O Setup menu
      Modular
      Press the Down Arrow key
      Press ENTER
    3. In the I/O Setup menu
      RS-232-C
      Press the Down Arrow key
      Press ENTER
    4. In the RS-232-C menu
      Config=Factory
      Press the Down Arrow key
      Press ENTER
    5. In the RS-232-C Setup menu
      Define Config
      Press ENTER
    6. In the Define Config menu
      Config A
      Press the Down Arrow key
      Press ENTER
    7. In the Config A menu
      Baudrate=9600
      Press ENTER
  3. Configure the serial interface to match your software configuration. This example changes the configuration to 19200 Baud and Even parity.
    1. In the Config A menu
      Baudrate=9600
      Press ENTER
    2. In the Baud Rate menu
      9600*
      Press the Up Arrow key
    3. In the Baud Rate menu
      19200
      Press ENTER
    4. In the Config A menu
      Baudrate=19200
      Press the Down Arrow key
    5. In the Config A menu
      Parity=None(0)
      Press ENTER
    6. In the Parity menu
      None(0)*
      Press the Down Arrow key
    7. In the Parity menu
      Even
      Press ENTER
    8. In the Config A menu
      Parity=Even
      Press ENTER
    Press Previous twice and the Down Arrow key once to return to RS-232-C Setup menu
    Config=Factory
  4. Switch to the new configuration.
    1. In the RS-232-C Setup menu
      Config=Factory
      Press ENTER
    2. In the RS-232-C CONFIGmenu
      Factory*
      Press the Down Arrow key
    3. In the RS-232-C CONFIG menu
      Config A
      Press ENTER
    4. In the RS-232-C SETUP menu
      Config A
      Press PREVIOUS until you return to
      STATUS
      Ready