The following table shows the settings available for the printer's serial interface parameters, the factory defaults, and the most likely requirements for different computers.
Serial (RS-232-C) Settings
|
Likely requirement for ...
|
||
Parameter
|
Available settings
|
PC
|
UNIX (R)
|
Baud rate
|
1200
2400
4800
9600*
19200
38400
|
9600*
|
9600*
|
Parity (1)
|
None (0)*
Even
Odd
|
None*
|
None*
|
* = factory default
note:Parity of None = 8 data bits, 1 stop bitParity of Even or Odd = 7 data bits, 1 stop bit
The settings on the printer must match those of the computer and software sending the data. Use their documentation to find the requirements. If in doubt, try with the above suggestions. If the printer's defaults already match the requirements, then you can skip the rest of this task.
To Change the Printer’s Serial Interface Settings
Through the front-panel display, you can create and save two sets of configurations for the serial interface, called Configurations A and B. By default, they are set to the factory defaults shown in the table above. The factory default configuration is always available as well, giving you up to three stored configurations to choose from.
The instructions that follow explain how to specify and apply Configuration A.
-
On the front-panel display, change the Menu mode from Short to Full.
-
Press ENTER.
-
Press the DOWN ARROW key twice to the Utilities menu. Press ENTER.Menu Mode = FullPress ENTER.Press the DOWN ARROW key to the Short menu mode. Press ENTER to save settings.In Short Menus
-
Choose Queuing and Nesting and press the Down Arrow key
-
Choose Demos and press the Down Arrow key
-
Choose Utilities and press the Down Arrow keyIn the Utilities menuShortPress ENTER
-
In the Menu modeShort *Press the Down Arrow key then press ENTER.
-
In the Utilities menuFullPress the Previous button
-
In the Full Menus modeUtilitiesPress the Down Arrow key
-
-
Go to the routine for defining a new serial configuration.
-
In the Full Menus modeI/O setupPress the Down Arrow keyPress ENTER
-
In the I/O Setup menuModularPress the Down Arrow keyPress ENTER
-
In the I/O Setup menuRS-232-CPress the Down Arrow keyPress ENTER
-
In the RS-232-C menuConfig=FactoryPress the Down Arrow keyPress ENTER
-
In the RS-232-C Setup menuDefine ConfigPress ENTER
-
In the Define Config menuConfig APress the Down Arrow keyPress ENTER
-
In the Config A menuBaudrate=9600Press ENTER
-
-
Configure the serial interface to match your software configuration. This example changes the configuration to 19200 Baud and Even parity.
-
In the Config A menuBaudrate=9600Press ENTER
-
In the Baud Rate menu9600*Press the Up Arrow key
-
In the Baud Rate menu19200Press ENTER
-
In the Config A menuBaudrate=19200Press the Down Arrow key
-
In the Config A menuParity=None(0)Press ENTER
-
In the Parity menuNone(0)*Press the Down Arrow key
-
In the Parity menuEvenPress ENTER
-
In the Config A menuParity=EvenPress ENTER
Press Previous twice and the Down Arrow key once to return to RS-232-C Setup menuConfig=Factory -
-
Switch to the new configuration.
-
In the RS-232-C Setup menuConfig=FactoryPress ENTER
-
In the RS-232-C CONFIGmenuFactory*Press the Down Arrow key
-
In the RS-232-C CONFIG menuConfig APress ENTER
-
In the RS-232-C SETUP menuConfig APress PREVIOUS until you return toSTATUSReady
-